| Prefabricated wooden constructions |
|
Frame (a skeleton) of construction made out of seasoned (humidity: 18%) spruce beams 60 x 120 or 160 mm, four-side planned. Ground beams are pressure impregnated. The space between shaving (OSB) plates, which close beam construction from both sides, is filled mineral wool. Total thickness of outer wall – ca 280 mm.
The insulation of outer walls – with corrugated polystyrene plates, fixed by bonding bars. Non-glue fixing of polystyrene plates to the OSB plates, covered additionally with wind-resisted foil, forms ventilating space. Moisture which reach under polystyrene plates is removed, the wall remains dry. Layers of outer walls (from outside to inside – thickness in mm): 1.glass-fibre net in glue – as a base of acrylate plaster (3-5 mm) 2.polystyrene plate (corrugated) (50 mm) 3.bonding bars + wind-resisted foil (0.15 mm) 4.shaving plate moisture-protected (the OSB-3) (12 mm) 5.frame (wooden) construction (160 mm) 6.mineral wool filled frame construction (160 mm) 7.vapour insulation (PE foil) (0.15 mm) 8.the OSB-3 plate (12 mm) 9.plaster plate (GKF) (12,5 mm). Layers of inner (bearing) walls: 1.the GKF plate (12.5 mm) 2.the OSB-3 plate (12 mm) 3.mineral wool (50 mm) 4.frame construction (120 mm) 5.the OSB-3 plate (12 mm) 6.the GKF plate (12.5 mm). Layers of inner (partition) walls: 1.the GKF plate (12.5 mm) 2.the OSB-3 plate (12 mm) 3.mineral wool (50 mm) 4.frame construction (100 mm) 5.the OSB-3 plate (12 mm). Bearing and partition walls are delivered and assembled in a hafl-opened system – with complete OSB and GKF plates, to assemble after installation. To the bathrooms and toilets we deliver water-resisted OSB plates. Layers of the ceiling construction (from the lowest to the highest layer): 1.the GKF plate (12.5 mm) 2.construction made out of wooden boards (25 mm) 3.vapour insulation (PE foil) (0.15 mm) 4.wooden construction made out of elements of 60 mm thickness (200 mm) 5.mineral wool in a strip 1.2 m wide from the outer walls (200 mm) 6.mineral wool on the remaining surface (50 mm) 7.the OSB-3 plate (12 mm). Layers of the ceiling over the garret: 1.the GKF plate (12.5 mm) 2.wooden construction - beams (25 mm) 3.vapour insulation (PE foil) (0.15 mm) 4.mineral wool filled the space between elements of wooden construction (200 mm) 5.spruce boards on all the surface of the roof (25 mm) 6.bituminous roof paper (or foil) (0.2 mm). The roof construction: rafters and other wooden beams (200 mm), seasoned and planned, prepared in accordance with plan, the roof foil, spruce boards. Outside woodwork: standard PVC windows, double glass K-1.1 W/w2K, frame k-1.4 Wm2K – built in. Window-sills made out of coated brass. Entrance door made out of PVC or wood, lacquered in the colour chosen by the customer. The foundations, chimneys, instalations, additional (finishing) works – they are a task of investor. |